Wiring Specifications
align="center"
All wiring should be done in accordance with the NEC (National Electric Code).
Recommended Wire and Conduit Sizes
For Residential Application
|
Wire sizes when used in conduit or underground: |
|
Size Panel |
Copper Phase |
Neutral |
Aluminum Phase |
Neutral |
|
|
*60 Amp |
#6 |
#6 |
#4 |
#6 |
|
100 Amp |
#4 |
#6 |
#2 |
#4 |
|
110 Amp |
#3 |
#4 |
#1 |
#2 |
|
125 Amp |
#2 |
#4 |
#1/0 |
#2 |
|
150 Amp |
#1 |
#2 |
#2/0 |
#1/0 |
|
175 Amp |
#1/0 |
#2 |
#3/0 |
#1/0 |
|
200 Amp |
#2/0 |
#1/0 |
#4/0 |
#2/0 |
|
225 Amp |
#4/0 |
#3/0 |
#4/0 |
#2/0 |
| *Should be used only for barns, small cabins, or small trailers. |
|
Conduit Sizes
|
|
Wire Size |
Conduit Size |
|
3- #6 |
1" |
|
2 - #4 and 1 - #6 |
1" |
|
2 - #3 and 1 - #4 |
1-1/4" |
|
2 - #2 and 1 - #4 |
1-1/4" |
|
2 - #1 and 1 - #2 |
1-1/4" |
|
2 - #1/0 and 1 - #2 |
1-1/2" |
|
2 - #2/0 and 1 - #1/0 |
1-1/2" |
|
2 - #3/0 and 1 - #1/0 |
2" |
|
2 - #4/0 and 1 - #2/0 |
2" |
|
Wire Sizes for Aluminum Overhead Triplex
|
|
100 Amp |
#2 Triplex |
|
110 Amp |
1/0 Triplex |
|
125 Amp |
1/0 Triplex |
|
150 Amp |
1/0 Triplex |
|
175 Amp |
3/0 Triplex |
|
200 Amp |
4/0 Triplex |
|
225 Amp |
4/0 Triplex |
|
Materials List 100 or 200 AMP Meter Base with Main Disconnect
|
|
Materials |
Quantity |
|
| 100 or 200 AMP Meter Base with Main Disconnect |
1 |
| Conduit (Rigid Aluminum recommended) |
15 ft. |
| Conduit Straps |
4 |
| Weatherhead |
1 |
| Weatherproof Hub |
1 |
| Wire (Size according to chart) |
As Required |
|
(Underground Services Only)
|
| Conduit - Schedule 80 PVC (NEMA) |
5 ft. |
| Threaded Adaptor |
1 |
| Conduit Locknut |
1 |
| Conduit Smooth Bushing |
2 |